Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Heart J Case Rep ; 7(9): ytad411, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37743895

RESUMO

Background: Coronary compromise is a serious potential complication following catheter ablation; however, procedural details in the literature are often lacking, preventing the identification of learning opportunities. Case summary: We report two cases of right coronary compromise following catheter ablation for symptomatic supraventricular tachycardia. After radiofrequency energy delivery at the coronary sinus ostium in both cases, inferior lead ST-elevation was observed. Diagnostic coronary angiography identified an occluded posterior left ventricular branch of the coronary artery, and optical coherence tomography demonstrated a high thrombus burden at this location. Electrocardiographic ST-segments settled with implantation of a drug-eluting stent. Discussion: Coronary compromise was likely secondary to energy delivery during catheter ablation. This case series highlights the need for electrophysiologist to understand coronary anatomy relative to anatomical landmarks, to anticipate the risk of vascular injury as physical distance from the site of ablation is likely important. Risk for coronary compromise, while a rare complication, needs to be discussed with patients during the consenting process. We also demonstrate the importance of an efficient multi-disciplinary team process for managing acute procedural complications.

2.
Pacing Clin Electrophysiol ; 44(4): 723-725, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33140464

RESUMO

A 52-year-old gentleman with a subcutaneous implantable cardioverter defibrillator (S-ICD) implanted in 2015 for primary prevention and a background of hypertrophic cardiomyopathy presented via remote monitoring alert (Boston Scientific Latitude NXT) with an aborted charge episode. The episode showed myopotential noise with baseline wander, and an urgent outpatient follow-up was arranged. Upon investigation the S-ICD lead had retracted to the pocket of the generator via a reel mechanism, wrapping the lead around the can. This was likely to be caused by insufficient suturing of the lead collar at the base of xiphisternum. The device had automatically disabled the SmartPass filter, which does not currently have an alert mechanism. This case highlights the rare occurrence of S-ICD lead displacement and components of the SmartPass system which can provide an early warning to lead problems.


Assuntos
Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Falha de Prótese , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...